232 SIGNAL COMMUNICATION DATA (2) Open wire pole line.-—Construction unit: 1 construction platoon of war-strength construction company (FM 11-20). 1 Type of construction. Iron pole line, 1 circuit on cross arm and single wire on top of poleIron pole line, 2 circuits on cross arms and single wire on top of poleLight pole line, 3 circuits on 6-pin cross arm. (Light 20- foot poles or 4 by 4's with 2 by 4's for cross arms withknob insulators) Standard pole line, 5 circuits on 10-pin cross arm. Poles to be serviced and set, using earth-boring ma chine Stringing wire on installed poles — addition of one 10-pin cross arm with 5 circuits Single-bracket line on installed poles 2 Weight of material in pounds per•mile 6,420 7,042 5,093 11,590 3,598 466 3 Average miles per S-hotir day a 3 2V4 2% 2 5 20 NOTE a. The rate at which open wire lines may be constructed will depend upon the size of the working party, the number of circuits required, the weather, and the type of terrain, and the facilities for distributing poles and materials. The chief factors are transportation and road congestion. The data listed above are based on the as sumption that the poles and material have been distributed along the route and that average conditions prevail. b. Normal talking range on wire circuits.—Using standard equip ment without repeaters, the normal talking ranges on nonloaded wire cir cuits are as follows: 1 Wire type W-38 W-73 W-74 W-108" W-110 W-110W-110-B W-110 B W-130, T-l W-130, T-l W-130, T-3 W-130, T-3 2 Range in miles 18 50 200 18 15 10 17 11 96 9 6 3 Weight (pounds ner mile) 240 39 166 216 132 132 132 132 31 31 49 49 4 Remarks Commercial outside distributing wire No. 17 AVVG bronze; 8-inch spacing, dry weather Commercial bare copper No. 10, AWG, 12- inch spacing, wet weather Commercial parallel drop wire Field wire, dry weather Field wire, wet weather Field wive, dry weather Field wire, wet weather Infantry assault wire, dry weather Infantry assault wire, wet weather Field Artillery assault wire, dry weather Field Artillery assault wire, wet weather 312

Original scan

Loading the original scan…
Original scan, PDF page 317. Only this page is downloaded. Open the full PDF

FM 101-10 Staff Officers Field Manual Organization Technical Logistical Data, PDF page 317

100%

Data on this page

1 data points

AttributeValue
Field wire line construction, war-strength construction company
construction unit1 construction platoon“Construction unit: 1 construction platoon”