FIELD ENGINEERING DATA 197 •ENEMY Z3ZZ3R& PARAPET ^GROUND LINE" FIflE CREST____ OMMAND T FRONT SLOPE" REVETMENT- •TRENCH BOARD 'DRAIN FIGURE 39—Trench nomenclature. PARADOS NOTE DIRT FROM C DISPOSED OF AT C' DIRT FROM A DISPOSED OF AT A' DIRT FROM B DISPOSED OF AT B' Simple standing trench, 9 sq. ft. excavation Type A, fire trench, 22 sq. ft. excavation Type B, fire trench, 28.5 sq. ft. excavation Type A, communications trench. (No fire step, no parapet, parados on both sides.) 17.5 sq. ft. excavation. FIGURE 40—Simple standing trench (Showing development into standard fire trench, types A and B). 28S .

Uncorrected OCR text. Columns and tables may be out of order; the scan is the authority.

Original scan

Loading the original scan…
Original scan, PDF page 288. Only this page is downloaded. Open the full PDF

FM 101-10 Staff Officers Field Manual Organization Technical Logistical Data, PDF page 288

100%

Data on this page

4 data points

AttributeValue
Simple standing trench
excavation area9 sq ft“Simple standing trench, 9 sq. ft. excavation”
Type A fire trench
excavation area22 sq ft“Type A, fire trench, 22 sq. ft. excavation”
Type B fire trench
excavation area28.5 sq ft“Type B, fire trench, 28.5 sq. ft. excavation”
Type A communications trench
excavation area17.5 sq ft“no parapet, parados on both sides.) 17.5”

Extracted from this page by machine. Each row quotes the text it came from; check it against the scan.