Skip to content
WW2 Information

Searchsoon

German Infantry Weapons (Special Series) (1943), p. 119

Page 119 of 203 in German Infantry Weapons (Special Series)

Transcription

GERMAN INFANTRY WEAPONS (2) Preparation for action.-(a) Set the base plate and bed it into the ground; set the ball-shaped section of the breech cap of the tube into the base-plate socket, with the flat section to the side. Turn the tube in the socket until the spring-actuated bolt is on top; spread the bipod legs, put the bipod in position with the elevating handwheel toward the tube, and see that the line formed by the bipod legs is parallel to the line formed by the forward edge of the base plate; open the mortar barrel clamp and set the elevation so that one-third of the elevating screw shows above its tube, and then place the barrel inside the clamp between the position marks on the barrel itself; place the sight on the sight base, tighten the mortar tube clamp, and set the sight to 1200; lay the mortar roughly by mov- ing the bipod legs and then set the legs by pressing the spikes into the ground. (3) Elevation.-Check the firing table (see table 3, p. 110, below) for the elevation necessary for the range and charge that you are using, and adjust the sight accordingly. Set the elevation clinometer by moving the elevating crank. (4) To zero mortar.-Sight the upper part of the sight on your aiming point or stake, and lay the mortar for direction by using the deflection adjustment on the sight. Note the angle shown on the deflection scale of the sight. (5) Determination of direction of fire.-Set up all aiming stake or select an aiming point in line with the target (see fig. 57). . With the deflection scale on the sight at zero degrees if the aiming point or stake is 106

Uncorrected OCR text. Columns and tables may be out of order; the scan is the authority.

Original scan

Loading the original scan…
Original scan, PDF page 119. Only this page is downloaded. Open the full PDF

German Infantry Weapons (Special Series), PDF page 119

100%

Data on this page

5 data points

AttributeValue
8-cm heavy mortar 34 sight
sight setting at preparation1200 sight units“set the sight to 1200”
8-cm heavy mortar 34 elevating screw
visible at preparationone-third“one-third of the elevating screw shows above its tube”
8-cm heavy mortar 34 direction
deflection for aiming point in frontzero“at zero degrees if the aiming point or stake is”
German 8-cm heavy mortar (s.Gr.W. 34, 81-mm)
sight setting on preparation1200 sight graduation“set the sight to 1200;”
elevating screw showing above tubeone-third“one-third of the elevating screw shows above its tube”

Extracted from this page by machine. Each row quotes the text it came from; check it against the scan.